XANTREX
CENTRAL INVERTER |
|
PART |
DESCRIPTION |
MSR |
OUR PRICE |
PURCHASE |
|
XAN-15015 |
PV20 20 kW, 3 phase inverter |
$15,452 |
$14,610 |
CALL
TO ORDER |
|
XAN-15018 |
PV15 15 kW, 3 phase inverter |
$12,220 |
$11,540 |
CALL
TO ORDER |
|
XAN-15022 |
PV10 10 kW, 3 phase inverter |
$8,473 |
$8,355 |
CALL
TO ORDER |
|
XAN-15023 |
PV30 30 kW, 3 phase inverter |
$20,989 |
$19,550 |
CALL
TO ORDER |
|
XAN-15025 |
PV15 15kW, 3 phase Inverter |
$12,220 |
$11,540 |
CALL
TO ORDER |
|
XAN-15026 |
PV20 20kW, 3 phase inverter |
$15,452 |
$14,610 |
CALL
TO ORDER |
|
XAN-15027 |
PV45 45kW, 3 phase inverter |
$26,647 |
$23,569 |
CALL
TO ORDER |
|
XAN-15028 |
PV100S-480-HE, 100kW,
480Vac, 3 phase
Inverter, with Transformer & AC/DC Disconnects |
$81,100 |
$76,000 |
CALL
TO ORDER |
|
XAN-15029 |
PV100S-208-HE 100kW, 208Vac, 3 phase
Inverter, with Iso. Transformer &
AC/DC Disconnects |
$81,100 |
$76,000 |
CALL
TO ORDER |
|
XAN-15030 |
PV150 150kW, 3 phase inverter |
$79,524 |
$77,258 |
CALL
TO ORDER |
|
XAN-15032 |
PV300 300kW, 3 phase inverter |
$123,529 |
$119,200 |
CALL
TO ORDER |
|
XAN-15034 |
PV225S-480-P 225kW, 480Vac, 3 phase
Inverter |
$128,846 |
$120,000 |
CALL
TO ORDER |
|
XAN-15819 |
Iso. Transform for PV20
208/120 volts |
$3,498 |
$3,345 |
CALL
TO ORDER |
|
XAN-15822 |
Iso. Transform for PV20 |
$3,498 |
$3,345 |
CALL
TO ORDER |
|
XAN-15823 |
Iso. Transform for PV10
208/120 volts |
$2,230 |
$2,135 |
CALL
TO ORDER |
|
XAN-15824 |
AC/DC disconn. for PV10 60
amp, 600 VDC |
$504 |
$485 |
CALL
TO ORDER |
|
XAN-15825 |
10 Circuit Combiner Box for
Xantrex Tech PV invert |
$581 |
$556 |
CALL
TO ORDER |
|
XAN-15826 |
Iso. Transform for PV10
208:480/277 volts |
$2,230 |
$2,134 |
CALL
TO ORDER |
|
XAN-15827 |
Iso. Transform for PV30 208:
480/277 Volt |
$4,079 |
$3,904 |
CALL
TO ORDER |
|
XAN-15828 |
AC Disconnect for PV30 60
amp, 480 VAC |
$504 |
$483 |
CALL
TO ORDER |
|
XAN-15829 |
DC Disconnect for PV30 200
amp, fusible |
$1,642 |
$1,571 |
CALL
TO ORDER |
|
XAN-15831 |
DC Disconnect for PV30
unfused, 600 VDC |
$1,014 |
$970 |
CALL
TO ORDER |
|
XAN-15832 |
Combiner Box - 12 Circuit,
NEMA 3R, fuses sold separately |
$756 |
$723 |
CALL
TO ORDER |
|
TOP
PV Series
Our PV Inverters are America's leading choice for
large-scale solar installations. These utility interactive, three-phase
inverters are available in models ranging from 10 kW to 225 kW. Multiple
inverters may be paralleled for larger power installations. For
information contact renewable energy sales team members John White, Sean
Hickey, and Andrew Nichols.
|
Model |
Waveform |
Continuous Watts |
Maximum Watts |
Portable or Hardwire |
| PV10 |
SW |
10 kW |
10 kW |
Hardwire |
| PV15 |
SW |
15 kW |
15 kW |
Hardwire |
| PV20 |
SW |
20 kW |
20 kW |
Hardwire |
| PV30 |
SW |
30 kW |
30 kW |
Hardwire |
| PV45 |
SW |
45 kW |
45 kW |
Hardwire |
| PV100 |
SW |
100 kW |
100 kW |
Hardwire |
| PV225 |
SW |
225 kW |
225 kW |
Hardwire |
|
|
 |
Description
Utility Interactive Renewable Energy
- Utility interactive, three-phase inverter, with models
ranging from 10 kW to 225 kW. Multiple inverters may be paralleled for
larger power installations.
- Designed for cost-effectiveness, high performance, easy
installation, and reliability.
- Advanced MPPT technology maximizes PV array output (not
for use with batteries).
- Revolutionary switching technology utilizes insulated
gate bi-polar transistors (IGBT), greatly reducing power losses during the
conversion process.
- Meets all applicable UL, IEEE, and NEC codes.
- Automatic operation includes start-up, shut-down,
self-diagnosis, and fault detection.
Features
- Efficient design, with over 95% peak efficiency for the
inverter, and overall efficiency including transformer losses, in excess
of 93%.
- Digital Signal Processor (DSP) based controls with
self-diagnostics and LCD for display of operating status.
- Inverter shut off and reset toggle switch.
- Over- and under-voltage and frequency protection,
shutting down the inverter in compliance with UL1741.
- Anti-islanding protection - prevents back-feeding
inverter-generated power to the grid in the event of a utility outage.
- User definable power tracking matches the inverter to
the array, as well as adjustable delay periods to customize system
shut-down sequences.
Options
- Variety of system accessories for ease of system
installation, including combiner boxes, isolation transformers, disconnect
switches, etc.
- Complete inverter kits, incorporating all required
accessories for NEC code compliant installation, are available.
Specifications Available
PV10
|
|
Electrical
Specifications |
|
|
Continuous Power
Rating |
|
10 kW |
|
|
Nominal AC Voltage |
|
208 VAC Three-phase,
+10% / -12% |
|
|
Nominal AC Frequency |
|
60 Hz +0.5 Hz / -0.7
Hz |
|
|
Line Power Factor |
|
>0.99 Above 20%
rated power |
|
|
Maximum AC Line
Current |
|
30.8 amps AC |
|
|
AC Current
Distortion |
|
<5% THD at rated
power |
|
|
Max. Open Circuit
Voltage |
|
600 VDC |
|
|
Power
Tracking
Window
Range |
|
330 to 600 VDC |
|
|
Max. DC Input
Current |
|
31.9 amps DC |
|
|
Max. Ripple Current |
|
<5% of rated current |
|
|
Peak Inverter
Efficiency |
|
>95% |
|
|
Standby Tare Losses |
|
<30 watts |
|
|
General
Specifications |
|
|
Temperature
Range: |
|
|
Ambient |
|
-4° F to 122° F
(-20° C to 50° C) |
|
|
Storage |
|
-40° F to 122° F
(-40° C to 50° C) |
|
|
Enclosure
Environmental Rating |
|
NEMA4 |
|
|
Enclosure
|
|
Galvaneal folded
steel enclosure |
|
|
Weight |
|
115 lb (52 kg) |
|
|
Dimensions (H x W x
D) |
|
26 x 16 x 12" (66 x
41 x 30 cm) |
|
|
Altitude |
|
6,600' (2,012 m) |
|
|
Relative Humidity |
|
0 to 95%
non-condensing |
|
|
Array Configuration |
|
Monopole, negative
grounded |
|
|
Features & Options |
|
|
Cooling Method |
|
PV10 - PV225: forced
convection cooling |
|
|
Protective Functions |
|
AC over/under
voltage, AC over/under frequency, ground over current, over
temperature, AC and DC over current, DC over voltage |
|
|
User Display |
|
Standard - LCD,
four-line, twenty-characters, with on/off toggle switch (LED status
indicators, only on PV5) |
|
|
AC Disconnect |
|
Optional - NEMA3R
wall mount enclosure, load break rated; Standard and integral to
inverter assembly for PV100 and PV225 |
|
|
DC Disconnect |
|
Optional - NEMA3R
wall mount enclosure, 600 VDC load break rated; Standard and integral
to inverter assembly for PV100 and PV225 |
|
|
| | | |